Lake Shore Cryotronics – Cryogenic Cable

Cryogenic Cable

Lake Shore Cryotronics

For high-frequency signals, Lake Shore provides various coaxial cables: ultra-miniature coaxial cables and semi-rigid coaxial with a stainless steel center conductor. We also offer the robust CryoCable™.

Ultra-Miniature Coaxial Cable — Type C, SC, SS

Ultra-miniature coaxial cable is for use when a strong and flexible cable is needed. Type C and SC are recommended when low conductor resistance is a prime consideration. Type SC and type SS are mechanically the most flexible, due to their braided construction. Type SS is recommended for use when both shielding and low thermal losses are important.

  Nominal Attenuation (dB/m)
  C(1) SC SS
1 MHz 0.092 0.108 0.569
5 MHz 0.167 0.240 1.272
10 MHz 0.224 0.344 1.799
15 MHz 0.257 0.421 2.850
20 MHz 0.294 0.486 2.545
50 MHz 0.427 0.769 4.031
100 MHz 0.623 1.090 5.694
500 MHz 1.312 2.453 12.749
1 GHz 1.886 3.488 18.048
2 GHz 2.625
5 GHz 7.968 40.526

1 Type C has a bandwidth to at least 3 GHz — above that, the aluminum/polyester becomes a less effective shield.

Thermal conductivity of copper units are W/(m • K)

  4 K 20 K 30 K 77 K 300 K
RRR8 = 20 122 719 870 502 397
RRR = 100 460 2460 2070 533 407

8 RRR = Residual Resistance Ratio.

Lake Shore Cryotronics - Thermal conductivity of copper units
  • Very flexible
  • Long flex life
  • Available in three configurations:
    • C — solid copper center conductor, drain wire, and aluminized/polyester shield
    • SC — stranded copper conductors
    • SS — stranded 304 stainless steel conductors

Semi-Rigid Coaxial Cable — Type SR

Coaxial cable frequency response specifications
Frequency (GHz) Insertion loss dB/m (dB/ft) Power CW (20 °C, sea level, W)
0.5 4.43 (1.35) 7.6
1.0 6.27 (1.91) 5.3
5.0 14.09 (4.30) 2.4
10.0 20.01 (6.10) 1.7
20.0 28.45 (8.67) 1.2

This cable transmits and receives high-speed, high-frequency microwave signals. Typically used for transmission lines in cryogenic-vacuum test systems.

To remove the outer conductor:

  • Score jacket
  • Bend at score until shield kinks, fatigues, and breaks
  • Slide off outer conductor

Extreme caution must be used in this process to avoid damage to the coax.

  • Easily bent, coiled, stripped, machined, soldered, or connected without impairing performance
  • Solid center conductor provides the optimum geometrical surface for transmission
  • Low standing wave ratio (SWR) with a dielectric controlled to exacting tolerances
  • Low thermal conductivity (≈0.4 W/(m · K) at 4.2 K)9
  • Matching minimizes reflective power loss
  • Provides shielding isolation for virtually no extraneous signal pickup Tubular outer conductor offers minimum size and maximum conductor integrity; stainless steel jacket can be soldered directly to circuit boards
  • 37 AWG, silver-plated copper-weld steel center conductor

9 Thermal conductivity at low temperatures is dominated by the copper cladding around the center conductor.

CryoCable™ — Type CRYC

Lake Shore Cryotronics – CryoCable™

CryoCable™ is a robust, 4-wire cable for use in cryogenic environments to room temperature. The cable is designed around 32 AWG (203 µm) diameter superconductive wires consisting of a NbTi core (128 µm diameter) and a Cu-10% Ni jacket.

Minimum bend radius: 15 mm (0.6 in)

Critical temperature: 9.8 K

Critical field: 10 T

Field Critical current (per wire)
3 T 35 A
5 T 25 A
7 T 15 A
9 T 6 A
  Temperature (K)
  295 77 4.2
Wire resistance (Ω/m) 9.2 8.4 010
Overbraid resistance (Ω/m) 0.90 0.64 0.62
Thermal conductivity — entire cable assembly (W/(m•K)) 7.6 2.8 0.17

10 Superconducting.

  • Robust:   the NbTi wire cores are strong and fatigue resistant, and the cable overbraid of 304 stainless steel adds significant strength and crush resistant
  • Low heat leak due to all-metal alloy and Teflon® construction
  • Solderable:   the CuNi wire surface is easy to solder with conventional rosin fluxes
  • Cryo-compatible:   all Teflon® (PFA) insulation is heat strippable for ease of preparation

Supplier Info

Lake Shore Cryotronics

For additional product information:

Visit Our Supplier's Website

Links to Lake Shore product page:

This website may use cookies to ensure you get the best experience on our website.
View our Privacy Policy.